031AV condenser fix / solution

Arborist Forum

Help Support Arborist Forum:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.

flyboy

ArboristSite Operative
Joined
Aug 5, 2008
Messages
436
Reaction score
38
Location
Bedford NH
I reverse engineered a stihl 031AV condenser.

I replaced it with a capacitor from Wima. It is an MKP4 0.22uF 630Volt 10%.

I started the saw at dusk with the pull start off and the windows in the flywheel open. I could not detect any arching on the points so I am calling it a good fix.

To install the capacitor....I soldered a couple wires to it and crimped 1 to the points and the other to one of the point mounting screws. I glued the capacitor to the block right next to the original condenser location using form-a-gasket.

Works great and hope this helps someone.

I have been reading this site for a couple years and decided I could finally contribute.
 
032AV Mega Fire

I a will be buying the Mega Fire II this week for my points 032AV. How do you like yours? Does it come with instructions to wire it? Thank you.

Trever
 

Latest posts