Lakeside53
Stihl Wrenching
Hmmm... Check the big round condensor (bottom left). If it's shorted or open (no charge capacity) then you might be able to repair the module. Also, meter the resistance on the two coils.
Last edited:
Hmmm... Check the big round condensor (bottom left). If it's shorted or open (no charge capacity) then you might be able to repair the module. Also, meter the resistance on the two coils.
Lake, I had to entertain a customer last night, but I will come back on this tomorrow...stay tuned..umpkin2:
thanks
Not that I have ever been aware of.
Belgian...try running a jumper wire from the stator plate screw to the case of the secondary coil.
You most likely have a bad or missing ground connection. (The AV requires a fairly heavy ground braid to electrically connect the isolated metal parts)
I assume you already tried removing the kill switch from the circuit.
Did the module come apart easily? Can you post a picture?
having problems with a Stihl 041 with low hours. excellent compression, starts right up, but when it warms up, starts backfiring. sounds like a small popping noise. then doesn't want to run. when the saw is cold, it starts to act normal until it warms up, then starts to backfire.
could the ignition module be going out?